Model
2001e Electrosurgical Unit
Full-Featured Electrosurgery for
the Office |
|
 |
 |
120 Watts Maximum Power Output
Perform office-based procedures
with confidence.
Five Distinct Output Modes
Cut, Coagulation, Blend, Fulguration and Bipolar outputs provide unsurpassed versatility.
Hand Control with Optional Foot Control
Fully adaptable to almost any procedure
or electrode.
| 9006501 |
Model 2001e
Electrosurgical Unit (110-210VAC)
(Includes: disposable hand-control pencil, disposable
patient pad, clamp-cord assembly, and manual) |
|
|
 |
Reusable
LOOP Electrodes
5 to 6 uses with proper care. Available
individually. |
|

All Premier Electrodes are made with tungsten wire and
fitted with a standard 3/32 diameter,
5
long shaft. A wide variety of shapes and sizes offered
to facilitate loop surgery. |
 |
 |
 |
| 1006310 |
Loop
(1.0cm x 1.0cm)
|
|
| 1006320 |
Loop
(1.5cm x 1.5cm)
|
|
| 1006330 |
Loop
(2.0cm x 1.2cm)
|
|
 |
 |
 |
| 1006315 |
Loop
(1.5cm x 0.8cm)
|
|
| 1006325 |
Loop
(2.0cm x 0.8cm)
|
|
|
|
 |
Disposable
LOOP Electrodes
Sterile, single-use electrodes.
Available in 5-packs. |
|
All Premier Electrodes are made with tungsten wire and
fitted
with a standard 3/32 diameter, 5 long shaft.
|
|
 |
TruCone
Rotational Cone Biopsy Electrode
|
|
 |
 |
- Improved Diagnosis
Produces a clean, smooth cut with minimum thermal
artifact. Sample conveniently secured.
- Patient Friendly, Safe
Insulated components ensure safety to the patient,
physician and staff.
Obtain Precise Cervical Cone
Biopsies Effortlessly!
| |
Diameter |
Depth |
|
| 9006110 |
18mm |
12mm |
| 9006115 |
18mm |
15mm |
| 9006125 |
24mm |
12mm |
| 9006130 |
24mm |
15mm |
| 9006140 |
30mm |
12mm |
| 9006145 |
30mm |
15mm |
| 9006165 |
30mm |
9mm |
| 9006170* |
12mm |
21mm |
9006175 Assorted Pack (3) 1 each:
18mm x 12mm,
18mm x 15mm, 24mm x 15mm |
* Stabilizer prongs not available on this size.
US Patent No. 5,676,663
|
|

With the electrosurgical generator in the active
mode, insert the appropriately sized TruCone
into the endocervical canal. (Use of a foot-controlled
generator
recommended.)
|

After the stabilizing prongs have secured the cervix,
gently rotate the shaft spindle for one complete rotation.
Hub serves as a rotation guide.
|

Deactivate generator and remove TruCone instrument
containing secured sample from vaginal cavity.
|
|
|
Order through your dealer
For information on Premier's complete line of Medical Products
contact Customer Service either by calling 888-670-6100
or 610-239-6000, or by e-mail at medinfo@premusa.com.
|
Back to Top
|